| Downloads |
|
|
|
| |
|

|

|
 |
Communication
and User Interface
• Standard 10/100BaseT Ethernet Port
• Expandable Serial Ports (Dual RS485 Ports)
• Modbus, Modbus TCP, DNP 3.0 Level 2
• 8 Simultaneous Connections via Ethernet
• Optional Second Ethernet Port
• Vivid 256 Color Display
• Optional 100BaseT Fiber Port
• Data Download Speed 20 Times Faster
Than Existing Technology |
New
Generation Transient Recording Power Quality
• 10MHz Transient Recorder (166,000 Samples per
Cycle)
• 8 Channel Waveform Recorder
• Voltage Surge, Sag and Transient Recording
• Current Fault Signatures and Analysis
• 1 Gigabyte Memory – Highly Extensive Recording
Capability
•
EN61000-4-30 Class A Certified |
|
Technology
Designed For Utilities and Industrial Users |
For
Energy Providers
(Utilities, Municipals, ESPs, Independents,
etc.)
-
Improve Substation Automation Solutions
- Increase
Power Distribution Reliability
- Record
Faults/Time Protective Equipment
- Monitor
Reliability of Breakers and Relays
- Shed
or Shift Loads Quickly
- Identify
and Manage Peak Demand
- Heighten
Response Time to PQ Events
- Enhance
Levels of Communication and Data Transmission
|
 |
For
Energy Consumers
(Industrial,
Commercial, Government, etc.)
-
Real Time PQ Monitoring and Analysis
- Efficiently
Control/Manage Energy Consumption
- Improve
Operational Efficiencies
- Increase
Productivity/Reduce Downtime
- Optimize
Loads/Extend Equipment Life
- Identify
and Respond to PQ Events Quickly
- Avoid
High Utility Penalties for Exceeding Usage
|
Accu-Measure™
Auto-Calibration Technology |
|

Real
Time Readings & Waveform Display

Historical Trends for Any Parameter |
EIG’s
patented Accu-Measure™ Auto-calibration
technology allows a field-mounted metering device
to achieve precision accuracy and maintain the
accuracy over temperature and time. This technique
is unique to EIG and consists of precise measurement
technology and high precision internal reference
standards.
Accu-Measure™
Technology features:
• 8 Independent High-Powered 16 Bit A/D
Converters.
• Dual Internal References for periodic
Auto-calibration.
• Internal temperature sensor to sense deviations
in instrument temperature.
• Designed to allow for repeatable and consistent
energy measurement results.
Benefits of Auto-Calibrating Technology:
• Improves accuracy over temperature.
• Improves repeatabilty, reducing meter
settling time.
• Improves long-term stability.
• Relies on precision internal DC references
to maintain accuracy.
Multipart
Approach to Precision in Accuracy
The
Nexus 1500 meter utilizes EIG’s Accu-measure™
technology, a technique based on a multipart approach
that allows a field-mounted metering device to
achieve laboratory accuracy.
|
 |
8
Independent 16 Bit A/D Converters
Eight 16 Bit A/D converters provide supreme
sampling accuracy and resolution —
no sample skews causing accuracy errors.
Dual
Internal References
The unit auto adjusts to dual internal references.
These references ensure that the monitoring
equipment maintains its calibration.
Auto-Calibration
with Temperature Compensation
The Nexus 1500 meter uses an auto-calibration
technique that recalibrates the unit on
the fly when the temperature changes more
than 5 degrees Centigrade, thereby monitoring
for accuracy over temperature.
Precision
Accuracy Specifications
With Accu-measure™ technology, this
unit far exceeds all ANSI C-12 and IEC 687
accuracy specifications. The unit offers
0.08% watt-hour accuracy. |
 |
|
|
V-Switch™
Technology |
|
|
The
Nexus 1500 meter is equipped with EIG’s
exclusive V-Switch™ technology, which enables
meter upgrades in the field without removing the
meter from service.
Nexus 1500 V-Switch™ keys include:
• V1: Standard Nexus 1500
meter with 128 Meg memory + 512 samples per cycle
• V2: V1 + 1 Gig total
memory + 1024 samples per cycle
• V3: V2 + 10MHz Transient
Recording |
 |
Detailed
Power Quality Recording |
|
|
16
Bit Waveform and Fault Recorder
The
unit records up to 1024 samples per cycle for
an event with 10MHz voltage transient sampling.
Voltage and current are recorded with pre- and
post-event analysis. Fault recording offers 8x
full scale capture capability. All voltage and
current readings are recorded using a 16 bit A/D
converter providing precise waveform resolution.
Both hardware and software triggers are available
to activate a waveform recording, which can be
used for power quality surveys, fault analysis,
breaker timing, etc.
High-Speed Status Input
Triggers
Waveforms are recorded at time of status change.
Input change and waveform recording are time-stamped
to a 1msec resolution.
EN61000-4-15 Flicker Meter
Flicker compliant with EN61000-4-15 standard.
Operates on both 220 Volt/50 Hz and 120Volt/50Hz
voltages throughout standard test points.
Subcycle Transient Recorder
The Nexus 1500 meter is equipped with 4 independent
10MHz analog to digital converters that measure
transient samples 10 million times per second.
The unit records subcycle transients on voltage
and current readings. It monitors switching noise
from capacitors, static transfer switches, SCRs
and many other “power quality harmful”
devices. Transients are often the cause of intermittent
and expensive periods of downtime. Without the
Nexus 1500 meter, solving these problems is often
impossible.
Independent ITIC/CBEMA
Log Plotting
Quickly view total surges, sags, and average duration
in the independent ITIC/CBEMA log.
Phasor
Analysis
The monitor provides a phase angle analysis between
the voltage and current channels, allowing for
efficiency and system-integrity analysis. |
 |
8
Channel Waveform Recorder

Phasor Analysis

Multi-Channel Waveform Recorder
|
EN6100-4-15
Flicker Compliance |
|
Sub-cycle
Transients with 10 MHz Pickup Frequency |
|
Multiple
Programmable Memory Logs |
|
|
Virtually
Unlimited Historical Trending Logs
The Nexus 1500 meter is equipped with vast amounts
of memory. A user can partition this memory for
log storage by setting up both the number of logs
and the number of parameters per log. Up to 8
historical logs can be created with up to 64 parameters
per log. With such extensive memory, the meter
can log for years.
Out Of Limit Log
The unit offers an independent out of limit log.
This allows a user to download out of limit information
to obtain a sequence of events for any occurrence.
Utilizing the 1msec clock resolution, the logs
can be combined with different metered points
throughout a distribution system to provide an
accurate system-wide depiction of a power disturbance.
Event-Triggered Waveform
Recording Log
The Nexus 1500 meter records waveforms with a
resolution of up to 1024 samples per cycle. The
amount of waveform recording is based on the amount
of memory installed.
The unit records the waveform when a value goes
out of limit and when the value returns to normal.
All information is time-stamped to the nearest
1msec. The 8 onboard High-Speed Inputs can be
tied to the waveform recording. Record when a
breaker tripped as compared to when the relay
activated. This is very useful for fault and breaker
integrity analysis.
The unit can be programmed to take more than one
recording every time an event occurs. Thousands
of cycles can be recorded per event.
ITIC/CBEMA Log
The Nexus 1500 meter stores a separate CBEMA log
that records magnitude and duration of voltage
and current surges and sags for every power quality
event. This allows the user to conduct real time
CBEMA analysis without downloading all stored
waveforms. The separate CBEMA log also allows
the unit to provide a more comprehensive picture
of power quality over time.
System Events Log
The Nexus 1500 meter logs extensive usage information
for detection of unauthorized access. The unit
records:
• Resets
• Programming changes
• Password Access Changes
• Time Changes
• Power Up / Power Down
• Change of Firmware
Input
Status Log
This log allows the user to record when the internal
inputs change status.
Uploadable Flash Memory
The Nexus 1500 meter utilizes uploadable flash
memory technology on all processors and DSPs located
in the unit. This insures that the unit can be
upgraded without removing it from service.
Set Limit Control
The Nexus 1500 power monitor provides programmable
setpoints for user settings. This feature allows
a user to configure the meter to be used as a
control device for many applications such as:
• Capacitor Control
• Load Shedding
• Automatic Transfer Schemes
• Transformer Monitoring & Control
• Redundant Protection (Not designed for
Primary Over-Current Protection)
• Many Other Control Functions
Waveform / Transient Logs
The Nexus 1500 can log waveform, utilizing its
programmable memory for all surges, sags and transients
within the scope of what it sees. Thousands of
events can be logged with resolution up to 1024
samples per cycle and transients at 10MHz resolution.
Custom Allocatable Memory
Structure
A user can custom define log sizes within the
meter. Thus the full memory can be allocated specifically
to the desired function. With EIG technology,
the meter can be configured optimally for your
application. |
 |

Extensive Historical Trending

Out of Limit Log

ITIC / CBEMA Trending

Extensive Memory Reads Data Indefinitely |

Configurable
Memory Allocation
|
|
|
Out
of Limit Log |
|
On-Board
Communication for Every Application
|
Standard
Communications:
• 100BaseT Ethernet RJ45 Port
• ANSI Optical Port
• Front cover USB port
Optional RS485 and Second
Ethernet Port:
• Two identical built-in serial ports: Up
to 115K baud.
• Standard protocols include Modbus RTU/ASCII
and DNP 3.0 Level 2.
• Also available, second Ethernet port,
either RJ45 or Fiber Optic.
8 Built-In Digital High-Speed
Status Inputs:
• Inputs automatically sense whether the
circuit is externally wetted.
• If externally wetted, input up to 300V
DC is accepted.
• If internally wetted, the meter supplies
the necessary voltage for the control application.
Sync. Check-Aux. Volt Input
—High-speed Vaux input can be used for:
• Neutral to ground.
• Voltage readings.
• Synchronizing schemes.
• Obtaining the frequency, magnitude, and
phase angle on both sides of a switch, or between
generator and bus voltage.
|
 |
 |
Industry
Leading DNP 3.0 Level 2 Plus —complies
with all DNP Level 1 and Level 2 certification
requirements, plus:
• Up to 136 measurements (64 Binary
Inputs, 8 Binary Counters, 64 Analog Inputs)
can be mapped to DNP static points in the
customizable DNP Point map.
• Up to 16 relays and 8 resets can be
controlled though DNP.
• Report-by-exception processing (DNP
Events) deadbands can be set on a per-point
basis.
• 250 available events, of combinations
of four events (Binary Input Change, Frozen
Counter, Counter Change, Analog Change).
• Available Freeze commands: Freeze,
Freeze/No-Ack, Freeze with Time, Freeze with
Time/No-Ack.
• Freeze with Time command enables the
meter to have internal time driven Frozen
Counter and Frozen counter event data.
• Third party certification is available.
• New programmable secondary scale allows
users to maximize 16 bit analog input resolution
precisely around the desired parameters providing
enhanced resolution to SCADA.
Rapid Response™
Ethernet:
• Rapid Response™ 10/100BaseT
Ethernet allows for 8 simultaneous connections
of Ethernet Modbus TCP protocol. One socket
for DNP 3.0 protocol is also available. Rapid
Response™ technology insures that the
Nexus meter is optimized to download data
as quickly as possible.
• Utilizing a novel Modbus TCP approach,
the meter will download up to 20 times faster
than existing Nexus 125X Series meters. No
long wait time to retrieve data.
|
|
|
Analog
Transducer Signal Outputs:
• 1mAON4/1mAON8: 4 or 8 Analog
Outputs, 0-1mA, self-powered, scalable,
bidirectional.
• 20mAON4/20mAON8: 4 or 8 Analog
Outputs, 4-20mA, self-powered, scalable.
Wiring: Common Mode.
Accuracy: 0.1% of Full Scale.
Calibration: Self-calibrating.
Scaling: Programmable.
Ordering: Up to 4 Analog Output modules
for each
Nexus 1500 meter. More than 2
Modules requires an external Power
Supply, Model #PSIO.
Digital Dry Contact
Relay Outputs:
• 4RO1: 4 Relay Outputs, 5 amps,
125 AC/DC,
Form C – Latching Relays.
• Ordering: Up to 4 modules can
be used.
Digital Solid
State Pulse Outputs:
• 4PO1: 4 Solid State Pulse Outputs,
Form A or C KYZ pulses.
• Maximum Pulse Speed: 20 pulses
per second.
• Ordering: Up to 4 modules can
be used.
Output Module
Accessories:
• PSIO: Additional power supply
for up to 4 Output modules. Needed when
using 3 or more displays and/or Output
modules. See manual for specific VA
allotments.
• MBIO: Mounting bracket for Output
modules. Must be ordered with output
module. |
|
|
|
|
|
A
Truly Beautiful Interface |
|
|
The Nexus 1500 meter features an LCD color display
with touch screen capability. The display uses
bright TFT glass with a high temperature and long
life LED backlight. LED is superior to CCFL solutions
due to better temperature and half-life specifications.
Screen displays include: |
|
•
Real-time viewing (voltage, current, power,
demand)
•
Accumulated energy and time of use readings
• Flicker readings
• Alarms
• Phasor analysis
• Harmonic spectrum analysis, and
waveforms
• Real time trending
• Log status
• Configuration settings
|
|
|
|
Advanced
Reporting and Analysis |
|
|
EN61000-4-15
Flicker and Compliance Monitoring
It
is important to maintain a source of high quality
power to insure efficient operations. One particular
source of disturbance that can have very negative
effects is Flicker. Flicker consists of low frequency
(less than 24 Hz) to intermittent line disturbances
on the power line. Aside from effects on equipment,
disturbances of this type can have negative effects
on people.
One
particular example of this is the flickering of
light sources that can affect humans in different
ways, depending on the severity.
The
Nexus
1500 meter
complies fully with the Flicker requirements of
EN61000-4-15 and includes:
-
Flicker Evaluation-Instantaneous readings suitable
for online monitoring; Short Term Readings (PST
- 10 Min)
-
Logging and monitoring - Long Term Readings (PLT
- 4 hour) - logging and monitoring
-
Polling - Pinst, Pst, Pst Max, Pst Min, Plt, Plt
Max, Plt Min values
-
Log Viewer (View graphed values Pst and Plt for
Va, Vb and Vc or displayed values including Max
and Min.) |
 |

EN61000-4-15 Flicker Anaysis |
Rapid
Response™ 100BaseT Ethernet |
|
|
The 10/100BaseT design allows the unit to speak
with 12 simultaneous sockets of Modbus TCP. The
standard 100BaseT Ethernet port allows multiple
users to access meter data without any interface.
• 8 Simultaneous Sockets Of Modbus Over
Ethernet Communication
• Multiple Sockets Means Multiple Users
Or Software Systems Can Reach Meter Simultaneously
|
 |
|
|
|
| |
|
| |
|
Electro Industries/GaugeTech 1800 Shames Dr. Westbury NY 11590
Tel: 1877-EIMETER Fax: 516-338-4741 ©2009
All Rights Reserved |
|